Fire Alarm Systems: Design, Installation, Inspection and Testing in Alberta
Webinaire
/ October 7, 21, 28, 2024
/
Code : 15-1005-ONL24
- APERÇU
- PROGRAMME
- FORMATEUR
APERÇU
After Participating in this course, you will be able to:
- Describe the types of fire alarm systems and their applications
- Recognize the basic and optional features of fire alarm systems
- Explain the requirements of Voice Communication Systems
- Relate the requirements of the National Building Code & Fire Code Alberta Editions
- Apply your knowledge to design a fire alarm system
Description
Only a well-designed and functioning fire alarm system can protect people and the building from a fire hazard. This course is designed to provide participants with the tools needed to design, install and maintain fire alarm systems in accordance with building and fire codes.
Course Outline
- Categories & types of fire alarm systems
- Functions of fire alarm systems
- Features of fire alarm systems
- Types of detection devices
- Analysis of ULC Standards
- Types of air sampling applications
- Audible signaling devices & ancillary systems
- National Building Code & Fire Code Alberta Edition requirements
Who Should Attend
Fire Alarm System Designers & Engineers • Installation & Service personnel • Electrical Project Engineers & Supervisors • Building Owners • Property Managers • Superintendents • Maintenance personnel • Building and Fire Inspectors
10:00 am to 6:00 pm Eastern (Will include the usual breaks)
Horaire : 10:00 AM - 6:00 PM EDT
voir le programme complet
PROGRAMME
Day I
Overview of Fire Alarm Systems and Applications
- Input, output, processing, response time, and annunciation
- Stand-alone
- Distributed
- Centralized
- Networking (local and degraded mode)
Categories and Types of Fire Alarm Systems
- Local, auxiliary, remote, and proprietary
- Conventional and addressable (analog and digital)
- Single-stage and two-stage systems
- Single- to three-channel voice communication
- Fire fighters telephone, indication, and paging
Standard and Optional Features of Fire Alarm Control Units
- Basic features, annunciation, and controls
- Electrical supervision
- Priority level of indication
- Alarm silence/inhibit
- Input/output mapping
- Requirement of the annunciation (local and remote)
- Circuit types Class A and B
- Conventional and addressable loops
- Response time
- Different types of faults and trouble
- Optional features such as suppression systems, alarm verification, voice, smoke control, and egress
- door securing
Compatibility of Input/Output Devices, Voice Communication Systems
- Initiating and signalling devices
- Interfacing voice systems, built-in and stand-alone
- Interfacing different makes of control units
Evaluation and Certification of Fire Alarm Equipment as Per ULC Standards
- How ULC evaluates and certifies control units according to CAN/ULC-S527
- Certification of field devices according to their respective CAN/ULC-500 series standards
- What is required in voice communication systems
- Evaluation of transponders and their role
- Primary and secondary power requirements
In-Depth Analysis of National Installation and Maintenance Standards
- CAN/ULC-S524 Standard for Installation of Fire Alarm Systems
- CAN/ULC-S536 Standard for Inspection and Testing of Fire Alarm Systems
- CAN/ULC-S537 Standard for Verification of Fire Alarms
- CAN/ULC-S1001 Standard for the Integration of Fire Protection Systems
Day II
Maintenance of Fire Alarm Systems and Access Level
- What level of access may be made available to the building owners/users and service companies
- (software controlled)
- Role of AHJ
- Responsibilities of the manufacturer
Automatic Sprinkler Systems
- Requirements for sprinkler flow alarms
- Types of flow alarms
- Requirements for sprinkler supervision
ULC Certificate Program and Starting a Listed Service Company
- Requirements and how to qualify for certificates
- How you can start and become a listed fire alarm service company
- Required qualifications and experience
National Fire Code – Alberta Edition
- What is required for fire alarm system and restorations
- Testing and maintenance
Customized Installation and Special Inspection
- How customized installation affects ULC certification
- What is required for special inspection
- Who can initiate the request for field inspection
- AHJ involvement and their requirements for issuing occupancy permits
Exercise
- Design of a fire alarm system for a Low Rise building
Day III
Types of Detection Devices
- Heat Detectors: types; spacing, and placement restrictions as per ULC S524
- Smoke Detectors: types; spacing and placement restrictions
- Flame Detectors: types; spacing and placement restrictions
- Air Duct Type Smoke Detectors: types; spacing, and placement restrictions
- Manual Stations: types and location requirements
VESDA Air Sampling Applications
- Overview of the purpose and type of areas protected by VESDA systems
Types of Audible Signaling Devices
- Bells; horns, and speakers: types and location requirements as per the Alberta Building Code
- Audibility level requirements as per the Alberta Building Code
Types of Ancillary Systems connected to Fire Alarm Systems
- Electromagnetic locking devices (maglocks)
- Hold Open devices
Exercise
- Design of a fire alarm system for a High Rise building
Workshop: Design/Layout of a Typical Fire Alarm System
Participants will have an opportunity to design a fire alarm system based on the knowledge gained from the course.
Inspection Checklist
An initial checklist will be provided and discussed. Participants will be able to keep the completed checklist for future reference
FORMATEUR

John Percy is Captain of Fire Prevention with the Cambridge Fire Department.
He has over 25 years of experience in the fire protection and fire service industries. He has experience enforcing the Ontario Fire & Building codes, fire investigations, education, media relations, and building plans examination review. He is currently registered (BCIN) as a Fire Protection Inspector with the Ministry of Municipal Affairs & Housing in Ontario.
VOUS N’ÊTES PAS INTERESSÉ PAR CE COURS ?
Nous visons toujours à améliorer la qualité de nos cours. Veuillez sélectionner les raisons pour lesquelles vous pensez que ce cours est inadéquat (Cochez toutes les cases qui s’appliquent).
Note d’évaluation pour cette formation
Évaluation globale de ce cours par ses participants précédents !
UNITÉS & FRAIS
Accumulez vos heures de formation continue avec le CIPE
Tous les cours du CIPE vous permettent d’obtenir vos Heures de formation continue; utiles pour ceux qui doivent accumuler et soumettre leurs Heures comme l’exige l’Ordre des ingénieurs du Québec (OIQ) et l’Ordre des technologues professionnels du Québec (OTPQ).
Ces exigences de formation prennent fin le 31 mars 2025 pour l’OIQ et le 30 avril 2025 pour l’OTPQ !
VOIR LES COURSFormation en entreprise
Les AVANTAGES de la formation de groupe en ligne :
- Efficacité et coût
- Des cours de grandes qualité
- Flexibilité
- Pratique
- Confidentialité
- Obtenez un certificat avec des Heures de formation continue
Brochure de cours
Le CIPE a un catalogue informatif en format PDF qui contient tous les cours à venir.
Téléchargez dès maintenant